HVAC Sequencer

Find by Part, Model or Description

Model, Part or Description

19

results

SD01-0842picture of SD01-0842
$171.91
IN STOCK
HVAC Sequencer 15 KW 2 Stage 3 Pole 1-110 ON 1-110 OFF

Part Numbers

01-0842

SD01-0843picture of SD01-0843
$69.76
IN STOCK
HVAC Sequencer 20 KW 2 Stage 4 Pole 1-110 ON 1-110 OFF

Part Numbers

01-0843

SD12S20picture of SD12S20
$58.51
IN STOCK
HVAC Sequencer 5 kW 30-90 ON 1-30 OFF Cycle/Hertz: 60 Hz | Full load amps: 6 | Ignition type: Intermittent | Stage: Single | Voltage: 208-230 VAC

Part Numbers

12S20

SD12S22picture of SD12S22
$31.70
OUT OF STOCK
HVAC Sequencer 10 kW 30-90 ON 1-30 OFF Cycle/Hertz: 60 Hz | Full load amps: 6 | Ignition type: Intermittent | Stage: Single | Time delay: 30 - 90 Seconds | Voltage: 208-230 VAC

Part Numbers

12S22

SD24A34-6picture of SD24A34-6
$52.72
IN STOCK
HVAC Electric Heat Sequencer 4 Switches On Timings 1-110 Sec. Off Timings 1-110 Sec. Application: Electric heating | Voltage: 240v 120v 480V | Switches: 4 | Timings: 2 | Timings On: 1-110 | Timings Off: 1-110 | Ambient conditions: -50 to 165ºF | A.C. Resistive: 3000W 6000W 25A 12.5A | Electrical ratings (AFL): 7 A @ 240 VAC 14.0 A @ 120 VAC | Electrical ratings (ALR): 42 A @ 240 VAC 72 A @ 120 VAC | Pilot duty rating: 125 VA @ 240 VAC 125 VA @ 120 VAC 480 VA @ 480 VAC

Part Numbers

24A34-6, TJ90Q106, AP4503010, 1398444, 33233, 44832, 611-233, GS106, Q106, TDR-35

SD42-23116-01picture of SD42-23116-01
$26.58
IN STOCK
HVAC Sequencing Relay 1-Pole SPST - NO (Normally Open) Heater 24 VAC / 0.2A Steady State / 0.9A Maximum Connections: 1/4 inch quick connects | Contact configuration: SPST - NO | Heater voltage (V): 24 | Heater wattage/ power consumption: 24 VAC / 0.2A steady state / 0.9A maximum | Motor FLA at 120V (A): Pole 1: 14 | Motor FLA at 230V (A): Pole 1: 7 | Motor FLA at 460V (A): Pole 1: 3 | Motor LRA at 120V (A): Pole 1: 72 | Motor LRA at 230V (A): Pole 1: 42 | Motor LRA at 460V (A): Pole 1: 18 | Mounting: Angle bracket w/two mounting holes | Number of poles: 1 | Off timing - Pole 1 (seconds): 40-90 | On timing - Pole 1 (seconds): 1-30 | Pilot duty rating at 120V (VA): Pole 1: 125 | Pilot duty rating at 230V (VA): Pole 1: 125 | Pilot duty rating at 460V (VA): Pole 1: 125 | Resistive rating at 120V (A): Pole 1: 25 | Resistive rating at 230V (A): Pole 1: 25 | Resistive rating at 460V (A): Pole 1: 12.5

Part Numbers

42-23116-01

SD42-23116-06picture of SD42-23116-06
$27.68
IN STOCK
HVAC Sequencing Relay 2-Pole DPST - NO (Normally Open) Heater 24 VAC / 0.2A Steady State / 0.55A Maximum Connections: 1/4 inch quick connects | Contact configuration: DPST - NO | Heater voltage (V): 24 | Heater wattage/ power consumption: 24 VAC / 0.2A steady state / 0.55A maximum | Motor FLA at 120V (A): Pole 1: 14 Pole 2: 14 | Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7 | Motor FLA at 460V (A): Pole 1: 3 Pole 2: 3 | Motor LRA at 120V (A): Pole 1: 72 Pole 2: 72 | Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42 | Motor LRA at 460V (A): Pole 1: 18 Pole 2: 18 | Mounting: Angle bracket w/two mounting holes | Number of poles: 2 | Off timing - Pole 1 (seconds): 90-160 | Off timing - Pole 2 (seconds): 30-60 | On timing - Pole 1 (seconds): 10-40 | On timing - Pole 2 (seconds): 30-60 | Pilot duty rating at 120V (VA): Pole 1: 125 Pole 2: 125 | Pilot duty rating at 230V (VA): Pole 1: 125 Pole 2: 125 | Pilot duty rating at 460V (VA): Pole 1: 125 Pole 2: 125 | Resistive rating at 120V (A): Pole 1: 25 Pole 2: 25 | Resistive rating at 230V (A): Pole 1: 25 Pole 2: 25 | Resistive rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5

Part Numbers

42-23116-06

SD42-23116-07picture of SD42-23116-07
$39.12
IN STOCK
HVAC Sequencing Relay 3-Pole TPST - NO (Normally Open) Heater 24 VAC / 0.2A Steady State / 0.55A Maximum Connections: 1/4 inch quick connects | Contact configuration: TPST - NO | Heater voltage (V): 24 | Heater wattage/ power consumption: 24 VAC / 0.2A steady state / 0.55A maximum | Motor FLA at 120V (A): Pole 1: 7 Pole 2: 7 Pole 3: 7 | Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7 Pole 3: 7 | Motor FLA at 460V (A): Pole 1: 3 Pole 2: 3 Pole 3: 3 | Motor LRA at 120V (A): Pole 1: 42 Pole 2: 42 Pole 3: 42 | Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42 Pole 3: 42 | Motor LRA at 460V (A): Pole 1: 18 Pole 2: 18 Pole 3: 18 | Mounting: Angle bracket w/two mounting holes | Number of poles: 3 | Off timing - Pole 1 (seconds): 90-150 | Off timing - Pole 2 (seconds): 30-60 | Off timing - Pole 3 (seconds): 30-60 | On timing - Pole 1 (seconds): 10-30 | On timing - Pole 2 (seconds): 10-30 | On timing - Pole 3 (seconds): 10-30 | Pilot duty rating at 120V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 | Pilot duty rating at 230V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 | Pilot duty rating at 460V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 | Resistive rating at 120V (A): Pole 1: 25 Pole 2: 25 Pole 3: 25 | Resistive rating at 230V (A): Pole 1: 25 Pole 2: 25 Pole 3: 25 | Resistive rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5 Pole 3: 12.5

Part Numbers

42-23116-07

SD42-23116-08picture of SD42-23116-08
$26.88
IN STOCK
HVAC Sequencing Relay 2-Pole DPST - NO (Normally Open) Heater 24 VAC / 0.2A Steady State / 0.55A Maximum Connections: 1/4 inch quick connects | Contact configuration: DPST - NO | Heater voltage (V) 24 | Heater wattage/ power consumption: 24 VAC / 0.2A steady state / 0.55A maximum | Motor FLA at 120V (A): Pole 1: 14 Pole 2: 14 | Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7 | Motor FLA at 460V (A): Pole 1: 3 Pole 2: 3 | Motor LRA at 120V (A): Pole 1: 72 Pole 2: 72 | Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42 | Motor LRA at 460V (A): Pole 1: 18 Pole 2: 18 | Mounting: Angle bracket w/two mounting holes | Number of poles: 2 | Off timing - Pole 1 (seconds): 30-60 | Off timing - Pole 2 (seconds): 30-60 | On timing - Pole 1 (seconds): 10-30 | On timing - Pole 2 (seconds): 10-30 | Pilot duty rating at 120V (VA): Pole 1: 125 Pole 2: 125 | Pilot duty rating at 230V (VA): Pole 1: 125 Pole 2: 125 | Pilot duty rating at 460V (VA): Pole 1: 125 Pole 2: 125 | Resistive rating at 120V (A): Pole 1: 25 Pole 2: 25 | Resistive rating at 230V (A): Pole 1: 25 Pole 2: 25 | Resistive rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5

Part Numbers

42-23116-08

SD42-23116-09picture of SD42-23116-09
$38.63
IN STOCK
HVAC Sequencing Relay 3-Pole TPST - NO (Normally Open) Heater 24 VAC / 0.2A Steady State / 0.55A Maximum Connections: 1/4 inch quick connects | Contact configuration: TPST - NO | Heater voltage (V): 24 | Heater wattage/ power consumption: 24 VAC / 0.2A steady state / 0.55A maximum | Motor FLA at 120V (A): Pole 1: 7 Pole 2: 7 Pole 3: 7 | Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7 Pole 3: 7 | Motor FLA at 460V (A): Pole 1: 3 Pole 2: 3 Pole 3: 3 | Motor LRA at 120V (A): Pole 1: 42 Pole 2: 42 Pole 3: 42 | Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42 Pole 3: 42 | Motor LRA at 460V (A): Pole 1: 18 Pole 2: 18 Pole 3: 18 | Mounting: Angle bracket w/two mounting holes | Number of poles: 3 | Off timing - Pole 1 (seconds): 30-60 | Off timing - Pole 2 (seconds): 30-60 | Off timing - Pole 3 (seconds) 30-60 | On timing - Pole 1 (seconds) 10-30 | On timing - Pole 2 (seconds): 10-30 | On timing - Pole 3 (seconds): 10-30 | Pilot duty rating at 120V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 | Pilot duty rating at 230V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 | Pilot duty rating at 460V (VA): Pole 1: 125 Pole 2: 125 Pole 3: 125 | Resistive rating at 120V (A): Pole 1: 25 Pole 2: 25 Pole 3: 25 | Resistive rating at 230V (A): Pole 1: 25 Pole 2: 25 Pole 3: 25 | Resistive rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5 Pole 3: 12.5

Part Numbers

42-23116-09

SD425079Apicture of SD425079A
$29.93
IN STOCK
HVAC Sequencing Relay 2-Pole DPST - NO (Normally Open) Combination rating at 230V (RES/FLA/LRA): 30A Max: 23A resistive & 7A FL | Connections: 1/4 inch quick connects | Contact configuration: DPST - NO | Heater voltage (V): 24 | Heater wattage/ power consumption: 24 VAC/.10A -.18A steady state/.35 - 1.0 amps peak for 0.8 sec. | Motor FLA at 120V (A): Pole 1: 14 Pole 2: 14 | Motor FLA at 230V (A): Pole 1: 7 Pole 2: 7 | Motor FLA at 460V (A): Pole 1: 4 Pole 2: 4 | Motor LRA at 120V (A): Pole 1: 72 Pole 2: 72 | Motor LRA at 230V (A): Pole 1: 42 Pole 2: 42 | Motor LRA at 460V (A): Pole 1: 24 Pole 2: 24 | Mounting: Flush mount plate w/mounting hole & tab | Number of poles: 2 | Off timing - Pole 1 (seconds): 1-30 | Off timing - Pole 2 (seconds): 1-30 | On timing - Pole 1 (seconds): 30-60 | On timing - Pole 2 (seconds): 30-60 | Pilot duty rating at 120V (VA): Pole 1: 125 Pole 2: 125 | Pilot duty rating at 230V (VA): Pole 1: 125 Pole 2: 125 | Pilot duty rating at 460V (VA): Pole 1: 125 Pole 2: 125 | Resistive rating at 120V (A): Pole 1: 25 Pole 2: 25 | Resistive rating at 230V (A): Pole 1: 25 Pole 2: 25 | Resistive rating at 460V (A): Pole 1: 12.5 Pole 2: 12.5

Part Numbers

425079A

SDNS101picture of SDNS101
$16.70
IN STOCK
Supplying Demand Q101 Furnace Heat Sequencer 1SPST 24 Volt On 1-20 Off 40-110

Part Numbers

2F20, 58C9701, B129096, 525-37322-000, ZC24A34-1, IES24A34-1, 24A34-1, 24A34-7, 24A34-13, 6000AONI-98, 33241, 33841, NS101

SDNS102picture of SDNS102
$20.99
IN STOCK
Supplying Demand Q102 Furnace Heat Sequencer 1SPST 24 Volt On 30-90 Off 1-30 Model Specific

Part Numbers

40CF680020, ZC24A34-2, IES24A34-2, 24A34-2, 6000AOIN-97, 33242, 33842, NS102

SDNS103picture of SDNS103
$22.49
IN STOCK
Supplying Demand Q103 HQ1056789 Furnace Heat Pump Sequencer 1DPST 24 Volt On 1-20 Off 40-110

Part Numbers

BT1256504, HQ1056789, HN67QC005, ZC24A34-3, 1ES24A34-3, 24A34-3, 6000AOIN-87, 60000EO-102, 33244, 33844, NS103

SDNS104picture of SDNS104
$21.99
IN STOCK
Supplying Demand Q104 HN67QC006 Furnace Heat Pump Sequencer 1DPST 24 Volt On 30-90 Off 1-30

Part Numbers

525-37325-000, ZC24A34-4, IES24A34-4, 24A34-4, 60000EO49, 33245, 33845, NS104

Supplying Demand Q105 3120A357 Furnace Heat Pump Sequencer 1DPST 1SPST 24 Volt On 1-110 Off 1-110

Part Numbers

3120A357, 525-37327-000, ZC24A34-5, IES24A34-5, 24A35-5, 24A34-54, 51172-32, 33232, 33832, NS105

SDNS106picture of SDNS106
$29.99
IN STOCK
Supplying Demand Q106 Furnace Heat Sequencer 2DPST 24Volt On 1-110 Off 1-110

Part Numbers

Q106, NS106

SDNS212Spicture of SDNS212S
$34.39
IN STOCK
HVAC Sequencer 24 Volt Double Pole Staged On 1-25 Sec. Off 50-110 Sec.

Part Numbers

NS212S

SDNS247picture of SDNS247
$25.00
IN STOCK
Supplying Demand Q108 HN67GJ002 Furnace Heat Pump Sequencer 1SPDT 24 Volt On 1-25 Off 65-115

Part Numbers

60000C0-27, B13707-38, Q108, NS247